Designed to eliminate up to 95% of boat roll, the
Seakeeper 26 is sized for vessels ~70-85 feet,
up to ~75 tons. Unlike traditional external fins, the
Seakeeper 26 has no outside appendages, requires
only modest electrical power, and can be installed
virtually anywhere on board.
Specifications
Weight:3,155 lbs (1,431 kg)
Dimensions:
52.7 L x 55.9 W x 39.6 H (inches)
1.341 L x 1.419 W x 1.00 H (meters)
Innovative Cooling System:
Patented cooling enables higher flywheel speeds for maximum performance in a compact, lightweight design.
Vacuum Sealed:
Vacuum encapsulation allows faster spin, reduced weight and power use, while protecting core components.
Active Control:
Actively manages gyro torque for effective stabilization at all speeds and sea conditions.
Small & Lightweight:
Weighs only a small fraction of the boat’s displacement.
Eliminate Boat Roll:
Eliminates up to 95% of boat roll, reducing fatigue, anxiety, and seasickness.
Flexible & Efficient:
Simple installation, quiet operation, and no generator necessary.
Intuitive Dash Display
Control your Seakeeper with the push of a button on our new user-friendly dash display.
Not only is the display simple to use, but it integrates into your existing dash units
for optimal performance.
Additional Specifications
Performance
Max Rated Speed: 5,000 RPM
Angular Momentum at Max Rated RPM: 26,000 N-M-S
Max Anti-rolling Torque at Max Rated RPM: 68,703 N-M
Spool-up Time to Max Rated RPM: 75 minutes (5,000 RPM)
Spool-up Time to Stabilization: 43 minutes (3,750 RPM)
Power Consumption
Spool-Up Power: 3,000 Watts Max
Operating Power: 1,375 – 3,000 Watts (Sea State Dependent)
AC Power Input: 20 Amps @ 208 – 230 VAC, 50/60 Hz, Single Phase
Control Power: 240 Watts
Control Power Input: 24 VDC @ 10 Amps Max
Seawater Pump Power Input / Over Current Protection: 230 VAC @ 5 Amps Max
Dimensions & Environment
Weight: 3,155 lbs (1,431 kg)
Envelope Dimensions: 52.7 L × 55.9 W × 39.4 H (Inches)
Envelope Dimensions: 1.341 L × 1.419 W × 1.00 H (Meters)
Noise Output: ~74 dB at 1 meter
Seawater Supply to Heat Exchanger: 4 GPM (15.1 LPM) minimum
Seawater Supply to Heat Exchanger: 8 GPM (30.3 LPM) maximum
Ambient Air Temperature: 32° – 140° F (0° – 60° C)